September 26, 2020
Car: Subaru 10 LGT, 08 & 12 forester, 06 legacy RIP
Problem:
The compressor on my 2010 grenaded a few month ago. The variable ac compressor only has a pulley, no clutch. I replaced it, the ac condenser and the expansion valve. It still won’t come on.
I hooked mine up to Subaru SSM3 scanner and when I command the ac solenoid or try to run the relearn procedure – it fails and says the compressor is in ‘protect mode’ I can’t find anything in the FSM about ‘protect mode’ or what triggers it.
No codes present in the AC module
I managed to get 72 PSI into the system by heating the can of Freon with a propane torch and then closing the lowside port. Pressure switch shows 58 MPa and does fluctuate with temperature.
Shows a commanded evap core temperature as well as actual.
It shows zero Freon flow, the compressor just will not engage.
Solution:
Looks like installing a new compressor requires using the SSM III to
run a variable compressor break-in drive cycle. Also – it notes that
when you install a new compressor, you need to fill the system with
refrigerant before starting the vehicle – if the vehicle is restarted
without filling the system, it says to replace the compressor!
Compressor Installation
Posted by: Emily white at
02:17 AM
| No Comments
| Add Comment
Post contains 227 words, total size 2 kb.